Topical Article

How to connect failure modes and risks in a risk management file

Posted on by Congenius

In September we shared an article from our Head of Quality Dr Dirk Hüber on the purpose and methodology differences between a Risk Analysis and a Failure Mode and Effects Analysis (FMEA). The article outlined how risks from a Risk Analysis and failure modes from a Design or Process FMEA are not independent from each other. In his follow-up article below, Dr Hüber explains how this relationship can be built into your risk management file in a transparent and manageable way.

First, a quick recap…

In the previous article, we explained that a design failure, a usability failure, or a software failure may lead to a risk for a patient. In a similar way, a process failure may lead to a design failure that in turn may also lead to a risk for a patient. Consequently, the risk arising from, for example, a design failure, must be assessed in the Risk Analysis. Furthermore, for a known risk, the design failure leading to that risk should be analysed in the Design FMEA. Where a process failure leads to a design failure, and where a design failure is caused by a process failure, the design failure and process failure must be analysed in the respective Design and Process FMEAs. In short, the Risk Analysis and the different FMEA types are connected to each other – they are not isolated documents.

This follow-up article aims to build upon the concepts developed in our previous piece, covering the structure of a risk management file, populating the content of a risk management file, and finally its formal implementation.

Structuring your risk management file

Reviewing the structure of a risk management file will enable us to map the relationship between the Risk Analysis and the different FMEA types. There are three layers within this relationship:

  • The Risk Analysis’ description of the risks to patient, user, and environment
  • The Design FMEA’s description of the product failures (whilst this layer includes all types of FMEAs that describe product failures including Usability and Software FMEAs, for simplicity we sweepingly call these Design-FMEA)
  • The Process FMEA’s description of failures in the manufacturing process(es)

In reality, both Design and Process FMEA will usually contain many FMEAs covering various aspects and scopes of the product and manufacturing process.

Our previous article outlined which elements constitute a risk and a failure. But how are these elements connected to each other when we want to establish the relationship depicted in the figure above?

The three elements describing a risk or a failure are connected by horizontally shifting the elements in each layer by one element against each other, as depicted in the figure above.

For example, if a (known) risk is caused by a (new) design failure, the hazardous situation or failure mode of the risk becomes the potential effect of the design failure, and the failure cause of the risk becomes the failure mode of the design failure. The failure cause of the (new) design failure must then be determined in the Design FMEA.

On the other hand, if a (known) design failure leads to a (new) risk, the potential effect of the design failure becomes the hazardous situation or failure mode of the risk, and the failure mode of the design failure becomes the failure cause of the risk. The harm to the patient, user, or environment must then be determined in the Risk Analysis.

A practical example

Let’s take this academic explanation and apply it to a simple, practical example.

Consider a prefilled syringe that will be administered to a patient. The harm to the patient that we want to analyse here is the potential feeling of pain when the syringe is administered to them. Below, the goal is to analyse why the patient may feel pain:

In a layer diagram, that looks like this:

This may remind you of something you’ve seen in a different context – the 5-Why principle, applied in risk management:

Populating your risk management file

As you work through your risk management file, you may trigger further ideas regarding the risks and failures already discovered:

For example:

  1. You might realise that another cause for the needle not being applied in a smooth way is a patient with needle phobia (like myself!)
  2. Another reason for there being no silicon oil on the needle could be that the nurse gives the needle an extra disinfection by wiping it (this is also a real-life example, as not all nurses know that needles have silicon oil on them to help reduce pain during administration)
  3. You might discover that there’s a potential problem with the oil applicator in your manufacturing process

So, after you have begun to analyse a risk top-down and its causes on a design and process level, you can start to populate your risk management file on the various levels with new risks and failures, which themselves will be escalated and de-escalated to higher and lower levels respectively for further analysis. Once you begin to analyse these escalated and de-escalated failures and risks, more ideas about further risks and failures may be stimulated, and so on.

This approach can be depicted as follows, whereby we assume we want to build a risk management file for a new product:

Of course, when completing the various documents within your risk management file, you should always apply an appropriate systematic, e.g.

  • Analyse all risks related to the harms in the harms list for the Risk Analysis based on the intended use and its reasonably foreseeable misuse, as well as identification of characteristics related to safety
  • Analyse all product specifications in the Design FMEA, a use case for the Usability FMEA, or a process flow for the Process FMEA

But when you additionally follow the explained logic of escalating and de-escalating risks and failures, practise has proven the ability to populate a Risk Analysis and FMEAs efficiently and effectively. This in turn will really help you to achieve good specifications for your product and manufacturing process, as all mitigations defined will be included in these specifications.

At this point we should remind ourselves that as Risk Analysis, Design FMEA, and Process FMEA evaluate different things, they are complementary to each other:

  • A Risk Analysis evaluates risks to a patient, user, or environment
  • A Design FMEA evaluates the effect of product failures on the functionality of the product
  • A Process FMEA evaluates the effect of process failures on the functionality of the manufacturing process

These entities are associated with one another, and the approach we’ve introduced here ensures the proper connection of these entities in the risk management file, so that all aspects of failures and risks related to a product may be covered appropriately.

Risk management must start very early in development and continue throughout the development stage to deploy its full value. Then once your product is in market and you need to maintain your risk management file, the same principles apply and help as you analyse any newly detected risks or failures.

Formal implementation

A risk management process following the approach we’ve outlined here may be implemented and maintained through a paper-based solution or with the help of an electronic tool. The key to ensuring successful implementation involves:

  • Building the necessary traceability between the various risk management files and other technical documentation files into the Risk Analysis and FMEA tables
  • Instilling a clear understanding amongst the risk management teams as to what is required where and when to avoid confusion, inconsistency, and wasted effort, and to leverage the full benefit of the effort put into the process

Finally, below we show as an example how a Risk Analysis table might be presented with these principles implemented, with some further hints on what needs to be included in your Risk Analysis to ensure compliance with the current version of EN ISO 14971.

Should you have a challenge relating to Risk Management, our Quality team is ready and happy to help. Simply get in touch to start the conversation.

Related News & Knowledge

×

Get in touch

If you have a challenge that you think we could help with, please feel free to get in touch in a way that suits you best. We look forward to speaking with you!

Get in touch

×

Request
a demo

Find out more about QMgeniuS by requesting a demo.

Simply fill out your details and click “Request a demo", then a member of the team will get back to you shortly.

Alternatively, feel free to give us a call on +41 44 741 04 04 to start the conversation. We look forward to hearing from you!

    ×

    Subscribe to our
    monthly knowledge update

    Stay informed and up to date with the latest industry news delivered direct to your inbox. You can tailor your preferences to prioritise what you'd like to hear about each month; be it MedTech news headlines, fact sheet resources on the latest regulations or longer articles covering timely topics across the wider MedTech industry.

    By clicking subscribe, you are signing up to receive a monthly newsletter from us containing MedTech news, industry insights and more from Congenius. Subscribing also gives you full access to all topical content on our website. For information on how your data is managed, see our privacy policy.